Cisco Semester
3 Threaded Case Study |
Cutsheet
Vertical Cross Connect | |||||||||
Device | Port # | Network | Media | Speed (Mbps) | Termination | Device | Port # | Distance (m) | Cable Length (m) |
Router A | E0 | Admin | Cat 6 UTP | 1000 | MDF | Admin Firewall | 1 | 0 | 1 |
Router A | E1 | Curr | Cat 6 UTP | 1000 | MDF | Curr Firewall | 1 | 0 | 1 |
Router B | E0 | Admin | Cat 6 UTP | 1000 | MDF | Admin Firewall | 1 | 0 | 1 |
Router B | E1 | Curr | Cat 6 UTP | 1000 | MDF | Curr Firewall | 1 | 0 | 1 |
Curr Switch 1 | 1 | Curr | Cat 6 UTP | 1000 | MDF | Curr Firewall | 3 | 0 | 1 |
Curr Switch 1 | 2 | Curr | Cat 6 UTP | 1000 | MDF | Curr Switch 2 | 1 | 0 | 1 |
Curr Switch 1 | 3 | Curr | Cat 6 UTP | 1000 | MDF | Curr Switch 3 | 1 | 0 | 1 |
Curr Switch 1 | 4 | Curr | Cat 6 UTP | 1000 | IDF 1 | Curr Switch 1 | 1 | 72 | 78 |
Curr Switch 1 | 5 | Curr | Cat 6 UTP | 1000 | IDF 1 | Curr Switch 2 | 1 | 72 | 78 |
Curr Switch 1 | 6 | Curr | Cat 6 UTP | 1000 | IDF 1 | Curr Switch 1 | 1 | 78 | 84 |
Curr Switch 1 | 7 | Curr | Cat 6 UTP | 1000 | IDF 2 | Curr Switch 2 | 1 | 78 | 84 |
Admin Switch 1 | 1 | Admin | Cat 6 UTP | 1000 | MDF | Admin Firewall | 2 | 0 | 1 |
Admin Switch 1 | 2 | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 1 | 72 | 78 |
Admin Switch 1 | 3 | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 1 | 78 | 84 |
Curr Switch DMZ | 1 | Curr | Cat 6 UTP | 1000 | MDF | Curr Firewall | 2 | 0 | 1 |
Admin Switch DMZ | 1 | Admin | Cat 6 UTP | 1000 | MDF | Admin Firewall | 2 | 0 | 1 |
Horizontal Cross Connect | |||||||||
Room | Wire ID | Network | Media | Speed (Mbps) | Termination | Device | Port # | Distance (m) | Cable Length (m) |
AB03 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 3 | 18 | 24 |
AB04 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 4 | 10 | 16 |
AB06 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 5 | 9 | 15 |
AB08 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 6 | 24 | 30 |
AB09 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 7 | 25 | 31 |
AB10 | O | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 8 | 20 | 26 |
A01 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 2 | 22 | 28 |
A01 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 3 | 22 | 28 |
A01 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 4 | 22 | 28 |
A01 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 9 | 22 | 28 |
A02 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 5 | 21 | 27 |
A02 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 6 | 21 | 27 |
A02 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 7 | 21 | 27 |
A02 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 10 | 21 | 27 |
A03 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 8 | 27 | 33 |
A03 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 9 | 27 | 33 |
A03 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 10 | 27 | 33 |
A03 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 11 | 27 | 33 |
A04 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 11 | 28 | 34 |
A04 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 12 | 28 | 34 |
A04 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 13 | 28 | 34 |
A04 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 12 | 28 | 34 |
A05 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 14 | 41 | 47 |
A05 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 15 | 41 | 47 |
A05 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 16 | 41 | 47 |
A05 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 13 | 41 | 47 |
A06 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 17 | 42 | 48 |
A06 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 18 | 42 | 48 |
A06 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 19 | 42 | 48 |
A06 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 14 | 42 | 48 |
A07 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 20 | 55 | 61 |
A07 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 21 | 55 | 61 |
A07 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 1 | 22 | 55 | 61 |
A07 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 15 | 55 | 61 |
A08 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 8 | 67 | 73 |
A08 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 9 | 67 | 73 |
A08 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 10 | 67 | 73 |
A08 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 4 | 67 | 73 |
A10 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 11 | 49 | 55 |
A10 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 12 | 49 | 55 |
A10 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 13 | 49 | 55 |
A10 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 5 | 49 | 55 |
A11 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 14 | 38 | 44 |
A11 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 15 | 38 | 44 |
A11 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 16 | 38 | 44 |
A11 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 6 | 38 | 44 |
A12 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 17 | 30 | 36 |
A12 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 18 | 30 | 36 |
A12 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 1 | 19 | 30 | 36 |
A12 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 7 | 30 | 36 |
A13 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 2 | 65 | 71 |
A13 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 3 | 65 | 71 |
A13 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 4 | 65 | 71 |
A13 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 8 | 65 | 71 |
A15 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 5 | 48 | 54 |
A15 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 6 | 48 | 54 |
A15 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 7 | 48 | 54 |
A15 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 9 | 48 | 54 |
A16 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 8 | 40 | 46 |
A16 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 9 | 40 | 46 |
A16 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 10 | 40 | 46 |
A16 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 10 | 40 | 46 |
A18 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 11 | 38 | 44 |
A18 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 12 | 38 | 44 |
A18 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 13 | 38 | 44 |
A18 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 11 | 38 | 44 |
A19 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 2 | 25 | 31 |
A19 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 3 | 25 | 31 |
A19 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 4 | 25 | 31 |
A19 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 16 | 25 | 31 |
A20 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 5 | 13 | 19 |
A20 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 6 | 13 | 19 |
A20 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 7 | 13 | 19 |
A20 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 17 | 13 | 19 |
A21 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 8 | 16 | 22 |
A21 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 9 | 16 | 22 |
A21 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 10 | 16 | 22 |
A21 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 18 | 16 | 22 |
A22 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 11 | 34 | 40 |
A22 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 12 | 34 | 40 |
A22 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 13 | 34 | 40 |
A22 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 19 | 34 | 40 |
A23 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 14 | 54 | 60 |
A23 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 15 | 54 | 60 |
A23 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 16 | 54 | 60 |
A23 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 20 | 54 | 60 |
A24 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 17 | 55 | 61 |
A24 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 18 | 55 | 61 |
A24 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 19 | 55 | 61 |
A24 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 21 | 55 | 61 |
A25 | A | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 20 | 50 | 56 |
A25 | B | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 21 | 50 | 56 |
A25 | C | Curr | Cat 6 UTP | 100 | IDF 1 | Curr Switch 2 | 22 | 50 | 56 |
A25 | D | Admin | Cat 6 UTP | 1000 | IDF 1 | Admin Switch 1 | 22 | 50 | 56 |
A26 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 14 | 49 | 55 |
A26 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 15 | 49 | 55 |
A26 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 16 | 49 | 55 |
A26 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 12 | 49 | 55 |
A27 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 17 | 36 | 42 |
A27 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 18 | 36 | 42 |
A27 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 19 | 36 | 42 |
A27 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 13 | 36 | 42 |
A29 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 20 | 12 | 18 |
A29 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 21 | 12 | 18 |
A29 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 22 | 12 | 18 |
A29 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 14 | 12 | 18 |
A30 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 23 | 20 | 26 |
A30 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 2 | 24 | 20 | 26 |
A30 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 2 | 20 | 26 |
A30 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 15 | 20 | 26 |
A31 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 3 | 9 | 15 |
A31 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 4 | 9 | 15 |
A31 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 5 | 9 | 15 |
A31 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 16 | 9 | 15 |
A32 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 6 | 10 | 16 |
A32 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 7 | 10 | 16 |
A32 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 8 | 10 | 16 |
A32 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 17 | 10 | 16 |
A33 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 9 | 20 | 26 |
A33 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 10 | 20 | 26 |
A33 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 11 | 20 | 26 |
A33 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 18 | 20 | 26 |
A34 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 12 | 11 | 17 |
A34 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 13 | 11 | 17 |
A34 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 14 | 11 | 17 |
A34 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 19 | 11 | 17 |
A35 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 15 | 29 | 35 |
A35 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 16 | 29 | 35 |
A35 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 17 | 29 | 35 |
A35 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 20 | 29 | 35 |
A36 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 18 | 35 | 41 |
A36 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 19 | 35 | 41 |
A36 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 20 | 35 | 41 |
A36 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 21 | 35 | 41 |
A37 | A | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 21 | 36 | 42 |
A37 | B | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 22 | 36 | 42 |
A37 | C | Curr | Cat 6 UTP | 100 | MDF | Curr Switch 3 | 23 | 36 | 42 |
A37 | D | Admin | Cat 6 UTP | 1000 | MDF | Admin Switch 1 | 22 | 36 | 42 |
MP01 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 2 | 75 | 81 |
MP01 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 3 | 75 | 81 |
MP01 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 4 | 75 | 81 |
MP01 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 2 | 75 | 81 |
MP02 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 5 | 63 | 69 |
MP02 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 6 | 63 | 69 |
MP02 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 7 | 63 | 69 |
MP02 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 3 | 63 | 69 |
MP03 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 8 | 54 | 60 |
MP03 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 9 | 54 | 60 |
MP03 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 10 | 54 | 60 |
MP03 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 4 | 54 | 60 |
MP04 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 11 | 32 | 38 |
MP04 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 12 | 32 | 38 |
MP04 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 13 | 32 | 38 |
MP04 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 5 | 32 | 38 |
MP05 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 14 | 28 | 34 |
MP05 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 15 | 28 | 34 |
MP05 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 16 | 28 | 34 |
MP05 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 6 | 28 | 34 |
P01 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 17 | 49 | 55 |
P01 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 18 | 49 | 55 |
P01 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 19 | 49 | 55 |
P01 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 7 | 49 | 55 |
P02 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 20 | 50 | 56 |
P02 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 21 | 50 | 56 |
P02 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 1 | 22 | 50 | 56 |
P02 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 8 | 50 | 56 |
P03 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 2 | 66 | 72 |
P03 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 3 | 66 | 72 |
P03 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 4 | 66 | 72 |
P03 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 9 | 66 | 72 |
P04 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 5 | 67 | 73 |
P04 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 6 | 67 | 73 |
P04 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 7 | 67 | 73 |
P04 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 10 | 67 | 73 |
P05 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 8 | 79 | 85 |
P05 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 9 | 79 | 85 |
P05 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 10 | 79 | 85 |
P05 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 11 | 79 | 85 |
P06 | A | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 11 | 78 | 84 |
P06 | B | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 12 | 78 | 84 |
P06 | C | Curr | Cat 6 UTP | 100 | IDF 2 | Curr Switch 2 | 13 | 78 | 84 |
P06 | D | Admin | Cat 6 UTP | 1000 | IDF 2 | Admin Switch 1 | 12 | 78 | 84 |
Total Cable Length: | 8758 | ||||||||
Max Cable Run Length: | 85 | ||||||||
Min Cable Run Length: | 15 | ||||||||
Average Cable Run Length: | 44 | ||||||||