Figure 6.11. In this diagram the power supply connections to the op amp are shown. The positive power supply connection goes to plus 12 volts. The negative power supply connection is grounded. The upper input terminal connects to the negative end of a 10 u f capacitor. The positive end goes through a 10 k ohm resistor to the inverting input of an op amp. The lower input terminal is grounded. A 200 k ohm resistor connects from plus 12 volts to the noninverting input. Another 200 k ohm resistor connects from the noninverting input to ground. A 100 k ohm resistor connects from the op amp output to the inverting input. The output of the op amp goes to the positive end of another 10 u f cap. The negative end goes to the upper output terminal. The lower terminal is grounded. End verbal description.
Go back.